BURNER CONTROL SIEMENS LME 21.330 C 2, LME 21.350 C 2 FOR GAS BURNER
Control Burner LME 21.330 C 2 dan LME 21.350 C 2 adalah Unit kontrol pembakar gas otomatis untuk memantau pembakar gas aliran paksa satu tahap atau dua tahap tanpa kontrol aktuator dengan keluaran panas rendah hingga sedang, dalam operasi terputus-putus. Pemantauan dengan sensor ionisasi ame atau sensor UV QRA bersama dengan AGQ3. Pengganti untuk LGB 21.330 A27, LMG 21.330 B27 dan LME 21.330 A2.
Data Teknis:
- Waktu pra-aerasi (t1): 30 detik
- Waktu keselamatan pertama (TSA): 3 detik
- Tegangan listrik: AC230 V -15%/+10%
- Frekuensi listrik: 50 … 60 Hz ±6%
- Konsumsi daya: 12 VA
- Kisaran suhu: -20 … +60°C
- Kelembapan udara: < 95% r.h.
- Kelas perlindungan: IP40 (pastikan dengan pemasangan)
- Dimensi: kira-kira. 91 x 62 x 62,5 (P x L x T dalam mm)
- Berat: sekitar 0,20 kg
Fungsi
LME 21.330 C 2, LME 21.350 C 2
Kontrol pembakar, 1 tahap, ion, t1=30 detik, TSA=3 detik, AC230V
Kontrol pembakar, tanpa basis plug-in, komputer mikro, program waktu dan fase tetap, operasi 1 tahap, terputus-putus, dengan ionisasi, t1 = 30 detik, TSA = 3 detik, tanpa aktuator, AC 230 V, 50/60 Hz.
Kontrol pembakar gas LME1…
LME2…
LME4…
Kontrol pembakar untuk pengawasan pembakar gas 1 atau 2 tahap atau pembakar gas berkapasitas kecil hingga sedang, dengan atau tanpa kipas dalam operasi terputus-putus.
LME dan Lembar Data ini ditujukan untuk digunakan oleh OEM yang mengintegrasikan kontrol pembakar dalam produk mereka.FITUR
Penggunaan
LME digunakan untuk memulai dan mengawasi pembakar gas 1 atau 2 tahap atau pembakar gas dalam operasi terputus-putus. Pengawasan nyala api dilakukan melalui probe ionisasi atau detektor nyala api UV QRA2 / QRA2(1) / QRA2(2) / QRA2.9 / QRA4.U / QRA10.C dengan unit tambahan AGQ3.xA27 untuk pembakar gas dengan aliran udara paksa, atau, dalam kasus nyala api biru, dengan detektor nyala api biru QRC1. Dalam hal dimensi rumah, LME identik dengan kontrol pembakar LGB dan kontrol pembakar LMG (lihat Ringkasan jenis).
Aplikasi sesuai dengan EN 676: Pembakar draft paksa untuk bahan bakar gas
Telah diuji dan disetujui sesuai dengan DIN EN 298
Deteksi tegangan rendah
Pengawasan tekanan udara dengan pemeriksaan fungsional sakelar tekanan udara selama
menyalakan dan mengoperasikan (tergantung pada jenisnya)
Fasilitas pengaturan ulang jarak jauh elektrik
Indikasi multiwarna dari status kesalahan dan pesan status operasional
Pembatasan memulai ulang
Urutan kontrol yang akurat berkat penanganan sinyal digital
Pengoperasian terputus-putus yang terkontrol setelah maksimum 24 jam pengoperasian terus-menerusType Lanjutan:
- LME11.230C2
- LME11.330C2
- LME21.130C1
- LME21.130C2
- LME21.230C2
- LME21.330C1
- LME21.330C2
- LME21.350C1
- LME21.350C2
- LME21.550C2
- LME22.131C2
- LME22.231C2
- LME22.232C2
- LME22.233C2
- LME22.331C1
- LME22.331C2
- LME23.331C2
- LME23.351C2
- LME41.051C2
- LME41.052C2
- LME41.053C2 *)
- LME41.054C2
- LME41.071C2
- LME41.091C2
- LME41.092C2
- LME44.056C2
- LME44.057C1
- LME44.057C2
- LME44.190C2
General Data
General unit data : Mains voltage AC 120 V +10%/-15% : AC 230 V +10%/-15% Mains frequency : 50…60 Hz ±6% Power consumption : 12 VA : External primary fuse (Si) 6.3 A (slow) : Weight : : Safety class I For applications without safe separation. (burner control with plug-in base) : Protection against electric shock is achieved through double or reinforced insulation. Provision for the protective earth connection is made in the plug-in base AGK11. : Type of shutdown or interruption for each Shutdown with micro switch, 1-pole : circuit Mode of operation type 2 B : Degree of protection IP40 Creepage distances and air gaps • Overvoltage category III • Rated surge voltage 4 kV at 230 V AC • Pollution degree 2 • Up to 2,000 m above sea level Software class Class C 2-channel structure Reaction time in the event of loss of flame Max. 1 s Perm. cable length terminal 1 Max. 1 m at a line capacitance of 100 pF/m , unshielded (max. 3 m at 15 pF/m) Perm. cable length from QRA2 / QRA2(1) / QRA2(2) / QRA2.9 / QRA4.U / QRA10.C to AGQ3.xA27 (lay separate cable). Max. 20 m at 100 pF/m, unshielded Multicore cables are not permitted. Remote lockout reset laid separately Max. 20 m at 100 pF/m, unshielded Perm. cable length terminals 8 and 10 Max. 20 m at 100 pF/m, unshielded (lay separate cable) Perm. cable lengths other terminals Max. 3 m at 100 pF/m, unshielded Permissible input voltage at terminals 6 and 11 120 V AC +10%/-15% 230 V AC +10%/-15% Possible input current at terminal 6 0.5 mA Possible input current at terminals 8 and 11 1 mA Perm. terminal load At cosj³0.6 At cosj = 1 Terminal 3 Max. 2.7 A Max. 3 A (15 A for max. 0.5 s ® only LME2) Terminals 4, 5, 7 and 9 (11) Max. 1.7 A Max. 2 A Terminal 10 Max. 1 A Max. 1 A Technical data (cont’d) Environmental conditions Storage EN 60721-3-1:1997 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -20…60 °C Humidity <95% r.h. Transport EN 60721-3-2:1997 Climatic conditions Class 2K2 Mechanical conditions Class 2M2 Temperature range -20…60 °C Humidity <95% r.h. Operation EN 60721-3-3:1995 + A2:1997 Climatic conditions Class 3K3 Mechanical conditions Class 3M3 Temperature range -20… 60 °C Humidity <95% r.h. Installation altitude Max. 2,000 m above sea level Hubungi Kami
PT. INDIRA MITRA BOILER
Gudang : Blk. D19 Jl. Utama Raya Perum Permata Sepatan No.21, Pisangan Jaya, Kec. Sepatan, Kabupaten Tangerang, Banten 15520Office : Emerald Residence Sepatan Ruko 8i, RT.026/RW.005, Kosambi, Kec. Sukadiri, Kabupaten Tangerang, Banten 15530Whatsapp : 0895 3287 02165Mobile : 0821 1185 1623Tlp : 021 5011 0567Email : wahyuidm86@gmail.comwahyuspi46@gmail.comReferensi : http://jualboiler.com -