JUAL CONTROL BURNER SIEMENS LME 22.131 C2, LME 22.232 C 2, LME 22.331 C 2
JUAL CONTROL BURNER SIEMENS LME 22.131 C2, LME 22.232 C 2, LME 22.331 C 2
-
JUAL CONTROL BURNER SIEMENS LME 22.131 C2, LME 22.232 C 2, LME 22.331 C 2
Product Article Number (Market Facing Number) : LME22.131C2 | 100925532 Product Description : LME22.131C2 – Burner control, 2-stage, ion, t1=7s, TSA=3s, actuator 12s, AC230V Product family : LME22.131C2 – Burner control, 2-stage, ion, t1=7s, TSA=3s, actuator 12s, AC230V Product Lifecycle (PLM) : PM300:Active Product Price data Price Group / Headquarter Price Group : List Price (w/o VAT) : Customer Price : Metal Factor : None Delivery information Export Control Regulations : AL : N / ECCN : N Factory Production Time : 5 Day/Days Net Weight (kg) : 0.130 Kg Product Dimensions (W x L x H) : Not available Packaging Dimension : Not available Package size unit of measure : CT Quantity Unit : 1 Piece Packaging Quantity : 1 Additional Product Information EAN : Not available UPC : Not available Commodity Code : 84169000 LKZ_FDB/ CatalogID : BT_Catalog Product Group : QBA7 Country of origin : Germany Compliance with the substance restrictions according to RoHS directive : Since: 2015.04.24 Product class : Not available WEEE (2012/19/EU) Take-Back Obligation : No REACH Art. 33 Duty to inform according to the current list of candidates : Classifications Product Article Number (Market Facing Number) : LME22.232C2 | 100925535 Product Description : LME22.232C2 – Burner control, 2-stage, ion, t1=20s, TSA=3s, actuator 20s, AC230V Product family : LME22.232C2 – Burner control, 2-stage, ion, t1=20s, TSA=3s, actuator 20s, AC230V Product Lifecycle (PLM) : PM300:Active Product Price data Price Group / Headquarter Price Group : List Price (w/o VAT) : Customer Price : Metal Factor : None Delivery information Export Control Regulations : AL : N / ECCN : N Factory Production Time : 5 Day/Days Net Weight (kg) : 0.130 Kg Product Dimensions (W x L x H) : Not available Packaging Dimension : Not available Package size unit of measure : CT Quantity Unit : 1 Piece Packaging Quantity : 1 Additional Product Information EAN : Not available UPC : Not available Commodity Code : 84169000 LKZ_FDB/ CatalogID : BT_Catalog Product Group : QBA7 Country of origin : Germany Compliance with the substance restrictions according to RoHS directive : Since: 2015.04.24 Product class : Not available WEEE (2012/19/EU) Take-Back Obligation : No REACH Art. 33 Duty to inform according to the current list of candidates : Classifications Product Article Number (Market Facing Number) : LME22.331C2 | 100925553 Product Description : LME22.331C2 – Burner control, 2-stage, ion, t1=30s, TSA=3s, actuator 12s, AC230V Product family : LME22.331C2 – Burner control, 2-stage, ion, t1=30s, TSA=3s, actuator 12s, AC230V Product Lifecycle (PLM) : PM300:Active Product Price data Price Group / Headquarter Price Group : List Price (w/o VAT) : Customer Price : Metal Factor : None Delivery information Export Control Regulations : AL : N / ECCN : N Factory Production Time : 5 Day/Days Net Weight (kg) : 0.130 Kg Product Dimensions (W x L x H) : Not available Packaging Dimension : Not available Package size unit of measure : CT Quantity Unit : 1 Piece Packaging Quantity : 1 Additional Product Information EAN : Not available UPC : Not available Commodity Code : 84169000 LKZ_FDB/ CatalogID : BT_Catalog Product Group : QBA7 Country of origin : Germany Compliance with the substance restrictions according to RoHS directive : Since: 2015.04.24 Product class : Not available WEEE (2012/19/EU) Take-Back Obligation : No REACH Art. 33 Duty to inform according to the current list of candidates : Classifications Not available Fungsi
LME 22.131 C2, LME 22.232 C 2, LME 22.331 C 2
Kontrol pembakar, 1 tahap, ion, t1=30 detik, TSA=3 detik, AC230V
Kontrol pembakar, tanpa basis plug-in, komputer mikro, program waktu dan fase tetap, operasi 1 tahap, terputus-putus, dengan ionisasi, t1 = 30 detik, TSA = 3 detik, tanpa aktuator, AC 230 V, 50/60 Hz.
Kontrol pembakar gas LME1…
LME2…
LME4…
Kontrol pembakar untuk pengawasan pembakar gas 1 atau 2 tahap atau pembakar gas berkapasitas kecil hingga sedang, dengan atau tanpa kipas dalam operasi terputus-putus.
LME dan Lembar Data ini ditujukan untuk digunakan oleh OEM yang mengintegrasikan kontrol pembakar dalam produk mereka.FITUR
Penggunaan
LME digunakan untuk memulai dan mengawasi pembakar gas 1 atau 2 tahap atau pembakar gas dalam operasi terputus-putus. Pengawasan nyala api dilakukan melalui probe ionisasi atau detektor nyala api UV QRA2 / QRA2(1) / QRA2(2) / QRA2.9 / QRA4.U / QRA10.C dengan unit tambahan AGQ3.xA27 untuk pembakar gas dengan aliran udara paksa, atau, dalam kasus nyala api biru, dengan detektor nyala api biru QRC1. Dalam hal dimensi rumah, LME identik dengan kontrol pembakar LGB dan kontrol pembakar LMG (lihat Ringkasan jenis).
Aplikasi sesuai dengan EN 676: Pembakar draft paksa untuk bahan bakar gas
Telah diuji dan disetujui sesuai dengan DIN EN 298
Deteksi tegangan rendah
Pengawasan tekanan udara dengan pemeriksaan fungsional sakelar tekanan udara selama
menyalakan dan mengoperasikan (tergantung pada jenisnya)
Fasilitas pengaturan ulang jarak jauh elektrik
Indikasi multiwarna dari status kesalahan dan pesan status operasional
Pembatasan memulai ulang
Urutan kontrol yang akurat berkat penanganan sinyal digital
Pengoperasian terputus-putus yang terkontrol setelah maksimum 24 jam pengoperasian terus-menerusType Lanjutan:
- LME11.230C2
- LME11.330C2
- LME21.130C1
- LME21.130C2
- LME21.230C2
- LME21.330C1
- LME21.330C2
- LME21.350C1
- LME21.350C2
- LME21.550C2
- LME22.131C2
- LME22.231C2
- LME22.232C2
- LME22.233C2
- LME22.331C1
- LME22.331C2
- LME23.331C2
- LME23.351C2
- LME41.051C2
- LME41.052C2
- LME41.053C2 *)
- LME41.054C2
- LME41.071C2
- LME41.091C2
- LME41.092C2
- LME44.056C2
- LME44.057C1
- LME44.057C2
- LME44.190C2
Hubungi Kami
PT. INDIRA MITRA BOILER
Gudang : Blk. D19 Jl. Utama Raya Perum Permata Sepatan No.21, Pisangan Jaya, Kec. Sepatan, Kabupaten Tangerang, Banten 15520Office : Emerald Residence Sepatan Ruko 8i, RT.026/RW.005, Kosambi, Kec. Sukadiri, Kabupaten Tangerang, Banten 15530Whatsapp : 0895 3287 02165Mobile : 0821 1185 1623Tlp : 021 5011 0567Email : wahyuidm86@gmail.comwahyuspi46@gmail.comReferensi : http://jualboiler.com -